The delay time determines how long the lock remains open after a valid entry. Enter Programming Mode. Press 4 + [00–99 Seconds] + # . Note: 00 sets the relay to toggle mode (latched). 6. Troubleshooting
To perform any administrative tasks, you must first enter .
If you forget your management password or wish to reset the system to its factory default state, follow these initialization steps. V2000-c Rfid Access Control User Manual
Normally Open (NO) – Connects to Fail-Secure locks (unlocks when energized). White: Common (COM) – Relay common terminal.
| J1 Connection | Relay Behavior | |:-------------|:---------------| | J1 Pins 1-2 connected | Normally Open (relay closes when activated) | | J1 Pins 2-3 connected | Normally Closed (relay opens when activated) | The delay time determines how long the lock
Enter Programming Mode →right arrow Press 1 →right arrow Swipe the RFID card →right arrow Press * . Add Card User by Specific ID Slot: Enter Programming Mode →right arrow Press 1 →right arrow Enter 3-to-4 digit User ID →right arrow Swipe the card →right arrow Press * . Add PIN User: Enter Programming Mode →right arrow Press 1 →right arrow Enter 3-to-4 digit User ID →right arrow Enter 4-digit PIN →right arrow Press # . Deleting Users Delete User by Card: Enter Programming Mode →right arrow Press 2 →right arrow Swipe the card →right arrow Press # . Delete User by ID Number: Enter Programming Mode →right arrow Press 2 →right arrow Enter User ID →right arrow Press # . Delete All Users: Enter Programming Mode →right arrow Press 2 →right arrow Press 0000 →right arrow Press # . Door Open Time Adjustment Set how long the lock stays unlocked after a valid entry. Enter Programming Mode. Press 4 + Time in Seconds (00–99) + # .
: Initialization only resets the system password to the factory default 12345 . All other user data (cards, PIN codes) remains intact. Note: 00 sets the relay to toggle mode (latched)
Press * followed immediately by your 6-digit Master Admin Code (The default out-of-the-box master code is 990101 or 123456 depending on production batch), then press # . The indicator status light will shift or flash, showing the terminal is ready for inputs.
Dedicated leads for external doorbell equipment activation. Programming Guide
If your V2000-c is connected to a networked access control system (such as Hanwha Techwin or AxxonSoft software), you can manage users via the software dashboard.
This usually indicates insufficient voltage or amperage from the power supply. Ensure the power supply outputs a stable 12V DC with at least 1.5A to 2A of current.