West 800-736-1712 | Central 800-944-0333 | East 678-354-9470

Bacset Software - ((link))

If you need a data scientist to set up a simple "if-then" rule, the software has failed. Look for intuitive interfaces with pre-built connectors for your common applications (Salesforce, SAP, MySQL, etc.).

Why are companies migrating away from spreadsheets and fragmented cloud tools? Here are the measurable benefits:

BACset's ability to generate configuration reports in CSV format enables seamless integration with third-party systems. Integrators can export configuration data, share it with BMS vendors, or import settings into other management platforms, ensuring consistent configuration across diverse building automation ecosystems.

Unlike generic BACnet tools that rely on time-consuming auto-discovery processes, BACset comes pre-loaded with intimate knowledge of pCOWeb and pCOnet features, including the types and quantities of BACnet objects supported, property configurations, and non-BACnet system functions. This pre-configured knowledge base dramatically speeds up the configuration process, eliminating the need for manual object discovery and property enumeration. bacset software

| Parameter | Description | Range | Factory Default | | :--- | :--- | :--- | :--- | | Device Instance | Unique BACnet device identifier | 0 - 4,194,303 | 77,000 | | Station Address | MS/TP network address (MAC address) | 0 - 127 | 0 | | Max Master | Highest allowable master address on network | 0 - 127 | 127 | | Max Info Frames | Maximum number of info frames per token pass | 0 - 255 | 20 | | Baud Rate | Communication speed for serial transmission | 9,600 - 76,800 bps | 38,400 bps |

┌────────────────────────┐ RS485-to-USB ┌────────────────────────┐ │ PC running BACset Software │ ──────────────────> │ CAREL pCOnet/pCOWeb Card │ └────────────────────────┘ └────────────────────────┘ │ │ ▼ Read / Write Properties ▼ Connected to ┌──────────────────────┐ ┌───────────────────────┐ │ Assign Station MACs │ │ CAREL pCO Controller │ │ Adjust Setpoints │ │ (Chiller, AHU, CRAC) │ └──────────────────────┘ └───────────────────────┘ Architectural Placement in Modern HVAC Projects

Note: While 1tool (2007) and c.suite (2014) are newer development tools from CAREL, BACset remains a staple for direct configuration of BACnet cards. Frequently Asked Questions If you need a data scientist to set

The configuration process using BACset allows system integrators to test communication without requiring the entire BMS infrastructure to be operational, streamlining commissioning and reducing downtime.

In building automation, CAREL pCO controllers manage complex HVAC, refrigeration, and cleanroom applications. To share data with an overarching BMS protocol like ASHRAE BACnet , these controllers use optional add-on serial cards.

Switch over to the , assign the network instance number specified by the building's master integrator, and click the Reboot command. Allow roughly 60 seconds for the serial card's onboard LED indicator to complete its restart sequence and flash steadily. 5. Verifying Real-Time Polling Accuracy Here are the measurable benefits: BACset's ability to

BACset allows precise configuration of essential BACnet MS/TP parameters that determine how devices communicate on the network:

Locate BACnet-compliant devices active on a network.

Confirm Windows Port properties are set precisely to 8 Data Bits and 2 Stop Bits. Version incompatibility with card firmware.

Once authenticated, search under the directory, filter down to the pCONet and pCOWeb platform files, and open the designated pCONet SE resource folder. Download the archived deployment package. When setting up a clean laptop environment, technicians must run the application found inside the BACSet_INSTALLER root directory first. This ensures that all vital system registries, driver frameworks, and background BACdoor client dependencies are properly written to the Windows operating system before executing the core program.

| Feature | Why It Matters | |---------|----------------| | | Basic device discovery across your network. | | ReadProperty / WriteProperty | Reading sensor values and adjusting setpoints. | | COV Subscription | Change of Value – efficient monitoring without polling. | | BACnet MS/TP or BACnet/IP | Support for your physical layer (RS-485 or Ethernet/IP). | | Device Object Discovery | List all points (Analog Inputs, Binary Outputs, etc.). |

Shares
Share This